User Manual
Software Version 2.7
© 2013 SurgeX / Electronic Systems Protection, Inc. / Technical Support: 1-800-645-9721 / surgex.com Page 9
III. HARDWARE
1. MULTIPAK:
a. Normal Operation
Plug the MULTIPAK input power cord into a properly grounded and compatible branch circuit
outlet; the green “System On” LED will illuminate.
b. Wiring Fault
When connected to an incorrectly wired branch circuit outlet, the Red LED will be illuminated.
c. Abnormal Voltage
When the magnitude of the branch circuit outlet voltage is not acceptable*, the MULTIPAK will
disconnect power to its outlets; refer to Section IV: Diagnostic Software for more information).
d. Clearing Memory
The MULTIPAK is able to timestamp the 60 most recent power quality events (information stored
in microcontroller non-volatile memory). The microcontroller memory contents can be cleared at
any time by following this method:
i. Diagnostic Software:
The device microcontroller memory may be cleared from within the Diagnostic Software
in the following location: “Tools/Clear Device Memory”. See Section IV – 4 - C: Tools
Menu, for details.
2. Data Interface Cable:
a. Overview
i. The MULTIPAK Data Interface Cable consists of a USB connection on one
end and an RJ-11 connection on the opposite end.
ii. The USB connection plugs into an available USB port on your PC. The RJ-
11 connection plugs into the RJ-11 jack (labeled “Data Port”) on the
MULTIPAK.
b. Instructions for Data Retrieval
i. Connect the MULTIPAK Data Interface Cable into the
USB port on your PC.
ii. Connect the MULTIPAK Data Interface Cable into the
RJ-11 jack (labeled “Data Port”) on the MULTIPAK
iii. Open the MULTIPAK Diagnostic Software.
Vue de la page 9